Dew Point Transmitter Blind Manufacturer
The AIDPT24 Dew Point Transmitter Blind by Aranka Instruments LLP is a microprocessor-based dew point transmitter designed for accurate and reliable dew point measurement across various industrial applications. Ideal for compressed air dryers, plastic dryers, gas quality testing, and additive manufacturing, this transmitter offers 4–20 mA output and RS-485 Modbus RTU communication for seamless system integration. As a leading Dew Point Transmitter Blind Manufacturer and Supplier in Ahmedabad, Gujarat, Aranka Instruments provides durable and high-performance transmitters that ensure precise humidity and moisture control in critical environments.
Why is knowledge of dew point in compressed air important?
The importance of dew point temperature in compressed air depends on the intended use of the air. In many cases dew point is not critical (portable compressors for pneumatic tools, gas station tire filling systems, etc.). In some cases, dew point is important only because the pipes that carry the air are exposed to freezing temperatures, where a high dew point could result in freezing and blockage of the pipes. In many modern factories, compressed air is used to operate a variety of equipment, some of which may malfunction if condensation forms on internal parts. Certain water sensitive processes (e.g. paint spraying) that require compressed air may have specific dryness specifications. Finally, medical and pharmaceutical processes may treat water vapor and other gases as contaminants, requiring a very high level of purity.
What is the typical range of dew point temperatures to be found in compressed air?
Dew point temperatures in compressed air range from ambient down to -80 °C (-112 °F), sometimes lower in special cases. Compressor systems without air drying capability tend to produce compressed air that is saturated at ambient temperature. Systems with refrigerant dryers pass the compressed air through some sort of cooled heat exchanger, causing water to condense out of the air stream. These systems typically produce air with a dew point no lower than 5 °C (23 °F). Desiccant drying systems absorb water vapor from the air stream and can produce air with a dew point of -40 °C (-40 °F) and drier if required.
What are the standards for the quality of compressed air?
ISO8573.1 is an international standard that specifies the quality of compressed air. The standard defines limits for three categories of air quality:
* Maximum particle size for any remaining particles
* Maximum allowable dew point temperature
* Maximum remaining oil content
Each category is given a quality class number between 1 and 6 according to the reference values shown in the table below. As an example, a system that conforms to ISO8573.1 and is rated for class 1.1.1 will provide air with a dew point no higher than -70 °C (-94 °F). All remaining particles in the air will be 0.1 um or smaller, and the maximum oil content will be 0.01 mg/m3. There are other standards for compressed air quality, such as ANSI/ISA- 7.0.01-1996 for instrument air.
- Fast Sensing Time.
- Dew Point, Humidity & Temperature can get By RS485 Modbus Communication.
- S.S.316 Filter.
- M12 Connector.
- IP67 protection.
Specification | Parameter | Description |
---|---|---|
Power | 24VDC | |
Range | -100 ~ 60°Cdp [Scalable] | |
Analog Output | 4–20mA | |
Communication | RS485 Modbus RTU | |
Sensor Connection | 3/4″ BSP Male | |
Sensor MOC | S.S. 304 | |
Flow Cell MOC | S.S. 304 | |
Interface Cable | 6 Meters | |
Filter MOC | S.S. 316 |
-
Compressed Air Systems:
-
HVAC Systems:
-
Industrial Drying Processes:
-
Metal Heat Treatment:
-
Breathing Air and Glove Box Monitoring:
-
Other Applications:
Frequently Asked Questions (FAQs)
What is the AIDPT24 Dew Point Transmitter Blind?
The AIDPT24 is a microprocessor-based dew point transmitter blind designed for monitoring moisture levels in gas/air streams. It outputs 4–20 mA analog and supports RS-485 Modbus RTU communication.
What is the measurement range (span) of the sensor?
It can measure dew point from –100 °Cdp to +60 °Cdp, and this range is scalable depending on application needs.
What process connection and materials are used?
The sensor has a ¾” BSP male connection, with wetted parts made of SS 304 and a 316 stainless steel filter.
What kind of outputs and communications are supported?
-
Analog output: 4–20 mA
-
Digital communication: RS-485 with Modbus RTU protocol
What protection and sealing does the transmitter offer?
It offers IP67 protection, making it dust-tight and water-resistant for harsh environments.
What are the typical applications of this dew point transmitter?
It’s used in compressed air systems, variable gas quality testing, plastic dryers, additive manufacturing, HVAC, industrial drying processes, and breathing air / glove box monitoring.
Why is measuring dew point in compressed air systems important?
Controlling dew point prevents condensation, corrosion, freezing, and ensures reliable operation of pneumatic equipment and quality in moisture-sensitive processes like pharmaceuticals, food, coatings, and paint spraying.
What power supply is required?
The transmitter operates on 24 VDC power.